Draka LMCJ03600 600 MCM 3C Lifeline MC Bare Stranded Copper LSZH Jacketed Two Hour Fire Resistive Cable
Allowable Ampacity for Draka LMCJ03600 600 MCM 3C Lifeline MC Bare Stranded Copper LSZH Jacketed Two Hour Fire Resistive Cable: 100 Amps
Applications:
Lifeline® MC LSZH fire resistive cables were designed to meet and have successfully passed the two-hour fire rating certification test per UL 2196, Standard for Tests for Fire Resistive Cables. Lifeline® MC LSZH Cables can be used in the following applications to provide survivability during a fire: - Emergency Feeder Cables - Ventilating Fans - Exit Lighting - Emergency lighting and ventilation for roadway and transit tunnels Lifeline® MC LSZH Cables are economical options for several life safety fire resistive applications in roadway and tunnel environments with a LSZH jacket to protect against corrosion. Fire resistive cables are required per NFPA 70, Articles 517, 695, 700, 708, 728 and 760 as well as NFPA 72 and NFPA 101.
Also Known as:
Fire Resistive Cable, Bare Copper Cable, MC LSZH Cables, MC Jacketed Cables, Draka Lifeline Cable, LMCJ03600
Specifications and Ratings:
• Listed to UL 1569, Metal Clad Cables, as the following type:
• Type MC 600 Volt, Rated 90°C
• For Wet Locations
• For Cable Tray Use IEEE 1202/ FT4 Rated, ST1 Limited Smoke
• Sunlight Resistance
• Direct Burial
• Classified to UL 2196, Standard for Tests for Fire Resistive Cables, for two-hours installations
• Electrical Circuit Integrity System (FHIT) No. 50 of the UL Fire Resistance Directory
• NFPA 70, NFPA 101, NFPA 130, NFPA 502 compliant
• Corrugated Copper Armor meets Equipment Grounding Conductor requirements of NEC Table 250.122
Design Parameters:
• CONDUCTORS: Bare stranded copper, 14 AWG through 600 kcmil
• INSULATION: Ceramifiable Silicone Zero Halogen (LSZH)
• INNER BINDER JACKET: Ceramifiable Silicone Zero Halogen (LSZH)
• ARMOR: Continuously Welded and Corrugated Copper
• JACKET: Thermoplastic Flame Resistant LSZH Jacket
• IDENTIFICATION: Lifeline® MC Jacketed Cables are marked as follows: DRAKA MA P/N [#########] [X]/C [Y] LIFELINE (UL) E66840T MC 600V 90C WET LOCS FOR CT USE IEEE 1202/FT4 ST1 SUN RES DIR BUR (UL) R19359 FRR 2HR UL 2196 ELECTRIC CIRCUIT INTEGRITY SYSTEM FHIT#50 480V UTILIZATION (MONTH/YEAR) (SEQUENTIAL FOOTAGE)
Notes: [#] is cable part number [X] is the number of conductors [Y] is the size of the cable in AWG or kcmil
Specification:
• Size AWG: 600
• Number of Cond: 3
• Nominal Core Diameter (in): 2.54
• Nominal Armor Diameter (in): 3.11
• Nominal Jacket Diameter (in): 3.28
• Ampacity* 75°C Amps: 420
• Ampacity* 90°C Amps: 475
• Net Weight: 7.2 lbs per ft
• Part Number: LMCJ03600
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color