Cable Gland PX2K Globally Metal Armour Clamping CMP SOLO LSF Barrier Explosive Atmosphere
Select a Variant
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
Cable Gland PX2K Globally Metal Armour Clamping CMP SOLO LSF Barrier Explosive Atmosphere
Also Known As:
Cable Gland, PX2K Cable Gland, Globally Gland, Armour Clamping Gland, CMP SOLO Gland, LSF Halogen Free Gland, Barrier Cable Gland
Construction:
• Design Specification: BS 6121:Part 1:1989, IEC 62444, EN 62444
• Mechanical Classifications *: Impact = Level 8, Retention = Class D
• Enclosure Protection: IK10 to IEC 62262 (20 Joules) Brass & Stainless Steel Only
• Electrical Classifications *: Category B (Category A When Used With Braid, Tape or Pliable Wire Armour Cables)
• ATEX Certificate: SIRA13ATEX1072X, SIRA13ATEX4078X
• Code of Protection: II 2G, II 1D, Ex d IIC Gb, Ex e IIC Gb, Ex ta IIIC Da II 3G Ex nR IIC Gc, IM2 Ex d I Mb, Ex e I Mb
• Compliance Standards: EN 60079-0,1,7,15,31
• IECEx Certificate: IECEx SIR 13.0027X, IECEx SIM 14.0008X
• Code of Protection: Ex d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex d I Mb, Ex e I Mb
• Compliance Standards: IEC 60079-0,1,7,15,31
• cCSAus Certificate (20s16 - 100): 2288626
• CSAus Code of Protection***: Class I, Div. 1, 2 Groups A, B, C and D; Class II, Div. 1, 2 Groups E, F and G; Class III, Div. 1, 2; Type 4X: Oil Resistant II: Class I, Zone 1 AEx d IIC Gb, AEx e IIC Gb, Class I, Zone 2 AEx nR IIC Gc, Class I, Zone 20 AEx ta IIIC Da
• cCSA Code of Protection***: Class I, Div. 1, 2 Groups A, B, C and D; Class II, Div. 1, 2 Groups E, F and G; Class III, Div. 1, 2; Type 4X: Oil Resistant II: Ex d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da
• Compliance Standards: CAN/CSA-C22.2 No 0,18,25,30,94,174, CAN/CSA-E60079-0,1,7,15,31 CAN/CSA-E61241-1-1 Part 1-1, ANSI/UL 514B Ed 5, ANSI/UL 50 Ed 11, ANSI/UL 2225 Ed 4, UL60079
• UL Certificate (20s16 - 100): E201187, E161256C
• Code of Protection: Class I Div 1,2, Groups A,B,C,D, Class II Div 1,2, Groups E,F,G
• Compliance Standards: UL 2225, CSA C22.2 No 174, UL 514B, CSA C22.2 No 18, CSA C22.2 No 30
• UkrSEPRO: UA.TR.047.C.0644-15
• EAC Certificate: C-GB.AA87.B.00487
• KCC Certificate: 14-GA4BO-0252X
• CCOE / PESO (India) Certificate: P333688
• NEPSI Certificate: GYJ13.1140X, GYJ13.1282X
• INMETRO Approval: TÜV 12.2073X
• RETIE Certificate: 03866
• RETIE Certificate: LRS: 01/00172, DNV: TAE00000Y, ABS: 14-LD234401A-4-PDA, BV: 43180/A1BV
• Ingress Protection Rating **: IP66, IP67 & IP68
• Deluge Protection Compliance: DTS01 : 91
• Cable Gland Material: Brass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium
• Seal Material: CMP SOLO LSF Halogen Free Thermoset Elastomer / Epoxy Barrier Compound
• Cable Type: Single Wire Armour (SWA), Aluminium Wire Armour (AWA), Wire Braid Armour (e.g. SWB), Screened Flexible (EMC) Wire Braid (e.g. CY / SY), Pliable Wire Armour (PWA), Steel Tape Armour (STA), Strip Armour (e.g. ASA)***
• Armour Clamping: Detachable Compound Tube / Cone & AnyWay Universal Clamping Ring
• Sealing Technique: Unique CMP ‘LRS’ Outer Seal (Load Retention Seal)
• Sealing Area(s): Inner Compound Barrier & Outer Sheath
• Optional Accessories: Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds, Ingress Discs
• Optional Installation Tools: Spanners, Armour Former Tool
Globally Approved, Explosive Atmosphere Barrier Cable Gland:
• Metal-to-Metal Armour Clamping
• Direct & Remote Installation
• Compound Barrier Type Flameproof Seal
• Controlled Outer ‘Load Retention’ Seal
• Unique OSTG Prevents Overtightening
• Integral Protected Deluge Seal
• -60°C to +85°C
• Class I Zone 1, 21 and Zone 2, 22 Class I Division 1 & 2 ABCD
• Globally Marked, IECEx, ATEX, UL & cCSAus
• EMC Tested