90 Cable Gland PX2KPB Metal Armour Clamping Lead Sheathed Barrier Expl
/products/90-cable-gland-px2kpb-metal-armour-clamping-lead-sheathed-barrier-explosive-atmosphere

Items in Cart ()

View cart

90 Cable Gland PX2KPB Metal Armour Clamping Lead Sheathed Barrier Explosive Atmosphere

90 Cable Gland PX2KPB Metal Armour Clamping Lead Sheathed Barrier Explosive Atmosphere
Roll over image to Zoom

90 Cable Gland PX2KPB Metal Armour Clamping Lead Sheathed Barrier Explosive Atmosphere

SKU:

Select a Variant

90 Cable Gland PX2KPB Metal Armour Clamping Lead Sheathed Barrier Explosive Atmosphere
Price:
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Quantity must be 1 or more

Customer Reviews

No reviews yet
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

90 Cable Gland PX2KPB Metal Armour Clamping Lead Sheathed Barrier Explosive Atmosphere

Allowable Ampacity
for 90 Cable Gland PX2KPB Metal Armour Clamping Lead Sheathed Barrier Explosive Atmosphere : 100 Amps


Also Known As:

Cable Gland, PX2KPB Gland, Armoured Gland, Atmosphere Gland, Lead Sheathed Gland, Metal Gland, Barrier Gland

Description :

• Effectively Earths / Grounds Lead Sheathed Cables
• Metal-to-metal Armour Clamping
• Direct & Remote Installation
• Compound Barrier Type Flameproof Seal
• Controlled Outer ‘Load Retention’ Seal
• Unique Ostg Prevents Overtightening
• Integral Protected Deluge Seal
• -60°C To +85°C
• Internationally Marked, Iecex & Atex
• Emc Tested

Construction :

Design Specification : BS 6121:Part 1:1989, IEC 62444, EN 62444
Mechanical Classifications : Impact = Level 8, Retention = Class D
Enclosure Protection : IK10 To IEC 62262 (20 Joules) Brass & Stainless Steel Only
Electrical Classifications : Category B (Category A when used with braid, tape or pliable wire armour cables)
ATEX Certificate : SIRA13ATEX1072X, SIRA13ATEX4078X
Code of Protection II 2G, II 1D, Ex d IIC Gb, Ex e IIC Gb, Ex ta IIIC Da,II 3G Ex nR IIC Gc, IM2 Ex d I Mb, Ex e I Mb
Compliance Standards : EN 60079-0,1,7,15,31
• IECEx Certificate : IECEx SIR 13.0027X, IECEx SIM 14.0008X
Code of Protection : Ex d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex d I Mb, Ex e I Mb
• Compliance Standards : IEC 60079-0,1,7,15,31
CCOE / PESO (India) Certificate : P333688
NEPSI Certificate : GYJ13.1140X, GYJ13.1282X
CCOE / PESO (India) Certificate : P333688
• INMETRO Approval : TUV 12.2073X
• RETIE Approval : 03866
• Marine Approvals : LRS: 01/00172, DNV: TAE000000Y, ABS: 14-LD234401A-4-PDA
Ingress Protection Rating : IP66, IP67 & IP68
Deluge Protection Compliance : DTS01 : 91
Cable Gland Material : Brass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium
Seal Material : CMP SOLO LSF Halogen Free Thermoset Elastomer / Epoxy Barrier Compound
• Cable Type : Lead Sheathed & Single Wire Armour (LC/SWA), Lead Sheathed & Aluminium Wire Armour (LC/AWA), Lead Sheathed & Wire Braid Armour (LC/SWB)
• Armour Clamping : Detachable Compound Tube / Cone & AnyWay Universal Clamping Ring
Sealing Technique : Unique CMP ‘LRS’ Outer Seal (Load Retention Seal)
• Sealing Area(s) : Inner Compound Barrier & Outer Sheath
• Optional Accessories : Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs
• Optional Installation Tools : 
Spanners

Specification :

• Cable Gland Size:
90
• Available Entry Threads "C" (Alternate Metric Thread Lengths Available) Standard Metric:
M90
Available Entry Threads "C" (Alternate Metric Thread Lengths Available) Standard Thread Length (Metric) "E": 24.0
• Available Entry Threads "C" (Alternate Metric Thread Lengths Available) Standard NPT:
3 ½
• Available Entry Threads "C" (Alternate Metric Thread Lengths Available) Standard Thread Length (NPT) "E":
42.8
• Available Entry Threads "C" (Alternate Metric Thread Lengths Available) Option NPT:
4
• Number of Cores:
200
• Diameter Over Conductors "A": 75.3
• Lead Sheath Diameter "G" Min:
66.6
• Lead Sheath Diameter "G" Max:
77.1
Overall Cable Diameter "B" Min: 76.2
• Overall Cable Diameter "B" Max:
90.3
Armour Range Grooved Cone (X) Min: 0.8
Armour Range Grooved Cone (X) Max: 1.6
Armour Range Stepped Cone (W) Min: 3.15
• Armour Range Stepped Cone (W) Max:
4.0
• Across Flats "D" Max:
115.0
Across Corners "D" Max: 126.5
Protrusion Length "F": 102.1
Combined Ordering Reference(*Brass Metric) Size: 90
Combined Ordering Reference (*Brass Metric) Type: PX2KPB
• Combined Ordering Reference (*Brass Metric) Ordering Suffix:
1RA
• Shroud:
PVC32
• Cable Gland Weight:
8.682 Lbs