4/3 TPU TYPE SHD-GC PORTABLE POWER MINING INDUSTRIAL CABLE 8000V
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
4/3 TPU Type SHD-GC Portable Power Mining Industrial Cable 8000V
Allowable Ampacity For 4/3 TPU Type SHD-GC Portable Power Mining Industrial Cable 8000v: 122 Amps
Applications:
TPU Type SHD-GC Portable Power Cable is designed for heavy-duty trailing cables on mining equipment where maximum safety is required. It is suitable for high voltage distribution in underground mines where portable power is necessary. The electrical cable is suitable for installation in ducts, troughs, and trays. SHD-GC cables are used for off-track equipment and power feeders of underground mines since they have dielectric strength, excellent resistivity, low flammability, good elongation capability, low flexural modulus, and excellent resistance to water absorption, oils, and fuels.
Also Known As:
4/3 Type SHD-GC TPU Cable, 4/3 Thermoplastic Polyurethane SHD-GC Portable Power Cable, 4/3 TPU Type SHD-GC Portable Power Cable, 4/3 Type SHD-GC Portable Power Shovel Cable, 4/3 SHD-GC TPU EPDM
Standards:
- MSHA listed
- Passes MSHA flame test (P-136-MSHA)
- Meets ICEA requirements
- OSHA acceptable
- Excellent resistance to oil, solvents, ozone, aging, and abrasion
- Moderate flexibility
- Passes MSHA flame test (P-136-MSHA)
- Suitable for continuous submersion in shallow water
Construction:
Conductor:
Flexible, rope stranded, uncoated annealed copper conductors per ICEA S-75-381 Paragraph 3.11 and ASTM B-3/B 173.
Tape:
A semi-conducting tape is applied over the conductor with a 10% minimum overlap. The tape shall meet the requirements of ICEA S-75-381 Paragraph 3.14. The separator is a ten mil nominal thickness semi-conducting tape colored black, white, and red is helically applied over the insulation with a 50% nominal overlap. The tape shall meet the requirements of ICEA S-75-381 Paragraph 3.17.
Insulation:
EPDM Ethylene Propylene Diene Monomer insulation is flexible, durable, and resistant to moisture.
Shield:
The shield is a tinned coated copper braid with an 85% minimum coverage and is applied over the taped and insulated conductor. It shall meet the requirements of ICEA S-75-381 Paragraph 3.19.1.1.
Ground Check Conductor:
The ground check conductor is a flexible rope-lay stranded, tin-coated annealed copper conductor insulated with 45 mils of a yellow insulating XLP compound.
Jacket:
The jacket is black, yellow, or orange as a standard offering of heavy-duty thermoplastic polyurethane (TPU).
Specification:
- AWG Size: 4/3
- Strands: 133
- Approx. Diameter INCHES: 1.900
- New Weight lb/1000FT: 1900 lbs
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460