18 AWG 25C Helukabel 62693 TrayControl 300 flexible PVC data cable

Where are we? 4 Continents 9 Countries


Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
18 AWG 25C Helukabel 62693 TrayControl 300 flexible PVC data cable
Applications:
TRAYCONTROL 300 is a flexible PVC data cable. The special combination of PLTC-ER and ITC-ER allows this cable to be used as a connecting cable for industrial plant and machinery in accordance with NFPA 79. Approved for open, unprotected installation in cable trays to the machine. Recommended applications: machine tools, control panels, control and instrumentation technology, production automation, cable ducts, and renewable energy. 22 – 16 AWG: resistant to UV radiation (SUN RES); 18 – 16 AWG: direct burial (DIR BUR). Only cables with 3 or more cores are rated for exposed run (ER).
Also Known As:
18 AWG 25C Traycontrol 300 cable, Helukabel flexible PVC cable, Tray rated data cable, Control and signal cable, 300V tray cable, 18 AWG 25C Flexible tray control wire, Industrial PVC control cable, Machine control data cable, UL listed tray cable, 18 AWG 25C Flexible instrumentation cable.
Technical Data:
PVC data cable acc. to UL-Std. 444 (CM), CSA-Std. C22.2 No. 214 - CMG, CSA-Std. C22.2 No. 210 - AWM I/II A/B, 28 AWG - 24 AWG: UL-Std. 758 (AWM) Style 2517, 22 AWG - 16
AWG: UL-Std. 2250 (ITC-ER), UL-Std. 13 (PLTC-ER), UL-Std. 758 (AWM) Style 2586
Temperature range
flexible +5°C to +50°C
fixed -25°C to +105°C
Nominal voltage
AC U 300 V
Test voltage core/core
2000 V
Minimum bending radius
flexible 8x Outer-Ø
fixed 4x Outer-Ø
Cable Structure:
• Copper wire tinned, finely stranded, AWG sizes
• Core insulation: see table
• Core identification acc. to company specifications, colour coded
• Cores stranded in layers with optimal lay lengths
• Separator
• Outer sheath: Special-PVC
• Sheath colour: grey (RAL 7001)
• Length marking: in feet.
Properties:
• resistant to: oil
• for outdoor use
• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
Tests:
• flame-retardant acc. to CSA FT4
• oil-resistant acc. to UL Std 13 No. 40, Oil Res I / Oil Res II
• Cold Bend Test acc. to UL Std. 13 No. 22
• Impact Test (-ER) acc. to UL Std. 13 No. 23
• Crushing Test (-ER) acc. to UL Std. 13 No. 24
• Vertical-Tray Flame Test (FT4) CSA-Std. C22.2 No. 2256
• certifications and approvals:
EAC
ECOLAB
Notes:
• Conductor sizes are based on the AWG measurement system, metric conductor sizes (mm²) are approximated and are for reference only
Specification:
• Size : 18 AWG
• No. cores x AWG-No. 25 x 18
• Cross-sec. mm², approx.: 0.96
• Outer Ø mm, approx: 17.4
• Cu factor per km: 231.1
• Weight kg/km, approx: 490.0
• Core insulation: PVC / Nylon