14 Polyrad Xt Flexible Rapid Transit Wire 2000v
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
Gauge | 14 |
---|---|
Conductor Stranding | 19/27 |
NOM. Diameter of Conductor | 0.067 |
O.D. Inches | 0.045 |
New Weight lb/1000FT | 22 lbs |
Nom. Insulation Thickness Inches | 0.128 |
Construction:
- Conductor: 20 AWG through 1111 kcmil soft annealed tinned copper
- Insulation: Polyrad XT Flame Retardant, Low Smoke Irradiated Cross-Linked Polyolefin (XLPO)
-
Options:
- Class K Stranding
- Available in colors other than dark gray
- Cables meeting NYCTA TX Specification available upon request
Applications:
- Ideally suited for use where environmental factors require cable characteristics to perform with a high degree of flame retardancy and excellent moisture-stable electrical values. Where reliability is the major concern and where maximum performance will be demanded
- Engineered and manufactured for both original equipment and retrofit use in power and control circuits, and in motor leads
- Extensively found on all types of heavy and light rail cars, rapid transit cars, diesel-electric locomotives, freight cars, wayside equipment and off-road vehicles
Features:
- Dual temperature rating at 125°C/110°C for long life, higher ampacities and protection from thermal overloads
- Excellent flexibility & free stripping
- Higher ampacities and simplified installations possible due to small outside diameters, flexible stranding and insulation
- Outstanding thermal stability at elevated temperatures
- Outstanding thermal stability at elevated temperatures
- Maximum flame retardance and low toxicity
- Excellent low-temperature performance; suitable for installation in sub zero conditions
- Extra tough, mechanically rugged Irradiated Thermoset Insulation
- Resistant to most oils and chemicals
- Meets cold bend test at -55°C
- Meets cold impact test at -40°C
Approvals:
-
Compliances:
- AAR S-501/AAR RP-585
- ICEA S-95-658
-
Compliances:
- IEEE 1202 (70,000 BTU/hr)
- IEEE 383 (70,000 BTU/hr)
- VW-1
-
Compliances:
- BSS 7239
- SMP 800-C
- ASTM E662
- Meets requirements of 49 CFR Part 238 for flame and smoke requirements
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet
Reviews
Get in Touch
Live Chat
Get replies right away!
Email
info@nassaunationalcable.com
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460