1000 '2 THHN THWN-2 Copper Building Wire | Nassau Cable
/products/1000-2-thhn-thwn-2-stranded-copper-building-wire

Items in Cart ()

View cart

1000' 2 THHN THWN-2 Stranded Copper Building Wire

1000' 2 THHN THWN-2 Stranded Copper Building Wire
Roll over image to Zoom
1000' 2 THHN THWN-2 Stranded Copper Building Wire
Roll over image to Zoom
1000' 2 THHN THWN-2 Stranded Copper Building Wire
Roll over image to Zoom
1000' 2 THHN THWN-2 Stranded Copper Building Wire
Roll over image to Zoom
1000' 2 THHN THWN-2 Stranded Copper Building Wire
Roll over image to Zoom
1000' 2 THHN THWN-2 Stranded Copper Building Wire
Roll over image to Zoom
1000' 2 THHN THWN-2 Stranded Copper Building Wire
Roll over image to Zoom
1000' 2 THHN THWN-2 Stranded Copper Building Wire
Roll over image to Zoom
1000' 2 THHN THWN-2 Stranded Copper Building Wire
Roll over image to Zoom

1000' 2 THHN THWN-2 Stranded Copper Building Wire

SKU: NNC2238X11
best-sellers

Select a Gauge

1000' 2 THHN THWN-2 Stranded Copper Building Wire

Availability: In stock

Price:
Regular price
$1,910.00 /Qty
Sale price
$1,910.00 /Qty
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

2 THHN THWN-2 Stranded Copper Building Wire

Applications:

SIMpull THHN/THWN-2 copper conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the National Electrical Code and other applicable codes and standards. Voltage for all applications is 600 volts. SIMpull THHN/THWN-2 copper conductors are designed to be installed without the application of a pulling lubricant. These conductors have multiple ratings depending upon the product application. 600 Volts. Copper Conductor. PVC Insulation/Nylon Sheath THHN/THWN-2. Heat, Moisture, Gasoline and Oil Resistant II.

Allowable temperatures are as follows:

- THHN or T90 Nylon- Dry locations not to exceed 90°C
- THWN-2 - Wet or dry locations not to exceed 90° C or locations not to exceed 75°C when exposed to oil
- TWN75- Wet locations not to exceed 75°C
- MTW- Wet locations or when exposed to oil at temperatures not to exceed 60°C or dry locations not to exceed 90°C (with ampacity limited to that for 75°C conductor temperature per NFPA 79)
- AWM- Dry locations not to exceed 105°C only when rated and used as appliance wiring material

Also Known As:

2 copper wire, 2 building cable, 2 hook up wire, 2 conduit wire, 2 nylon wire, 2 construction cable, 2 thermoplastic-insulated copper wire, 2 THHN-PVC tray cable, 2 CU THHN THWN-2, 2 CU Building Wire, 2 Black Stranded CU SIMpull THHN Wire, Southwire 20502102, Southwire Wire, 2 Gauge Black Stranded Copper THHN Wire, 2 AWG THHN/THWN-2 Wire, 2 AWG THHN/THWN-2 Copper Building Wire, 2 Black Stranded CU SIMpull THHN Wire, 2 AWG CU Wire, 2 AWG Strand Copper Wire, Nylon copper wire.

Construction:

    Conductor: 

    THHN THWN-2 conductors are constructed of annealed soft copper that follow ASTM B787 and ASTM B8 standard. 

    Insulation:

    The cable is insulated with a thermoset plastic jacket (PVC) that is flame-retardant, sunlight-resistant, lead-free, strong, and stable. Without being too bulky, it ensures that the cable can be used in harsh conditions. The jacket is color-coded in accordance with ICEA Method 4.

    Sheath:

    Nylon jacket utilizing SIMpull Technology

    Features:

    • Sunlight resistant #8 AWG and larger
    • Gasoline and Oil Resistant II
    • CT Rated 1/0 AWG and Larger
    • VW-1 All Sizes
    • FT-1 All Sizes
    • AWM- Sizes 14 through 6 AWG
    • MTW- Stranded Constructions Only
    • RoHS Compliant
    • LEED v4.1 Materials & Resources Credit MRc6; PBT (Lead Content Below 300 ppm Threshold)

    Standards:

    • ASTM B8 Concentric-Lay-Stranded Copper Conductors
    • ASTM B787 19 Wire Combination Unilay-Stranded Copper Conductors
    • UL 83 Thermoplastic Insulated Wires and Cables
    • UL 758 Standard for Appliance Wiring Material
    • UL 1063 Machine Tool Wiring (MTW)
    • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
    • CSA C22.2 No. 75 Thermoplastic Insulated Wires and Cables
    • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
    • Federal Specication A-A-59544
    • NMX-J-010-ANCE Thermoplastic insulated wires and cables
    • NOM-063-SCFI Electrical Products – Conductors – Safety Requirements

    Specifications:

    • Size : 2 AWG
    • Number of  Strands: 19
    • Diameter Over Conductor ( Inch ): 0.286
    • Insulation Thickness (mils): 41
    • Jacket Thickness (mils): 7
    • Aprox. OD (inches): 0.382
    • Copper Weight ( lbs/mft ): 204 lbs
    • Net Weight  ( lbs/mft ): 235 lbs
    • Minimum Bend Radius: 1.5 inch
    • Max Pull Tension: 530 lb
    • Allowable Ampacity At 75°C: 115 Amp
    • Allowable Ampacity At 90°C: 135 Amp
    • Southwire Part ( SimPull): 20502102

    Compatible with Manufacturer

    AWC : 

    Black : THHN 2 19 0
    White : THHN 2 19 9
    Red : THHN 2 19 2
    Blue : THHN 2 19 6
    Green : THHN 2 19 5
    Yellow : THHN 2 19 4
    Brown : THHN 2 19 1
    Orange : THHN 2 19 3
    Violet : THHN 2 19 7
    Gray : THHN 2 19 8

    Omni Cable :

    Black : M502ST-01
    White : M502ST-02
    Red : M502ST-03
    Green : M502ST-04
    Blue : M502ST-05
    Gray : M502ST-06
    Orange : M502ST-07
    Yellow : M502ST-08
    Purple : M502ST-09
    Brown : M502ST-10
    Pink : M502ST-11
    Tan : M502ST-12

    Southwire :

    White: 20503902
    Green : 29583201
    Black : 20502102
    Red : 20501302
    Blue : 31581202
    Gray : 61017201
    Orange : 61017101
    Yellow : 42065302
    Purple : 55253499
    Brown : 61016901

    Houston Wire:

    HW00100201


    *Data provided on this page is subject to change based on different manufacturers' variances
    ** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
    In the case the material only comes in a predetermined color or doesn’t come with any color

    Download PDF Spec Sheet

    FAQ's

    What are the particular applications of 2 AWG THHN?
    • Service feeds
    • Large subpanels
    • Heavy-duty HVAC systems
    • EV charging stations
    • Industrial machinery
    • Outdoor and underground projects
    What does THHN stand for?

    THHN stands for "Thermoplastic High Heat-resistant Nylon-coated."

    What is THHN Wire suitable for?

    THHN wire is suitable for electrical conduits, indoor and outdoor use (as long as ranked THWN), building wire across industries, and control circuits.

    Can THHN Be Direct Buried?

    THHN does not have an appropriate rating for direct burial because of its construction, but THHN/THWN-2 with a double rating can.

    Does THHN Have to Be in Conduit?

    Yes, THHN must always be installed in the conduit as per NEC. The only exception to this rule is when THHN is installed in control panels.

    Is THHN Rated for Wet Locations?

    THHN is rated for dry locations, while THWN is rated for wet locations.

    Can THHN Be Used in Underground Conduit?

    The wire used for the underground conduit should have a THWN-2 rating for wet locations.

    Can You Run THHN in Walls?

    You can run THHN wire in walls within conduit or raceway, but NM-B wire is generally a more popular option for indoor wiring.

    Can you use THHN wire for automotive?

    Using THHN wire for automotive applications is not recommended.

    Is THHN wire waterproof?

    THHN/THWN is not waterproof. While it is suited for wet environments, it cannot be directly submerged in water.

    Reviews

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Get in Touch
    Live Chat Get replies right away!
    Email info@nassaunationalcable.com

    Call Us: 1-516-482-6313    Text Us: 1-516-703-3460