10 AWG 37C Shielded Copper PE/PVC Insulation PVC Jacket Control Cable 600V
Where are we? 4 Continents 9 Countries

Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
10 AWG 37C Shielded Copper PE/PVC Insulation PVC Jacket Control Cable 600V
Applications:
The 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.
Control Cable 600 Volt Copper Conductors, Polyethylene Polyvinyl Chloride (PE/PVC) Insulation Shielded Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.
Also Known AS:
10 AWG 37C Shielded Control Cable, 10 AWG 37C Instrumentation Cable, Multi-Core Shielded Control Cable, 10 AWG 37C Shielded, Multi-Conductor Cable, Control & Signal Cable, Screened Control Cable, Industrial Control Cable, 10 AWG 37C Automation Cable.
Standards:
• ASTM B3 Standard Specification for Soft or Annealed Copper Wire
• ASTM B8 Concentric-Lay-Stranded Copper Conductors
• CSA CSA marking is available upon request
• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1
• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables
• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu/hr) and ICEA T-29-520 - (210,000 Btu/hr)
• VW-1 (Vertical-Wire) Flame Test
Construction:
Conductor:
7 strands class B compressed bare copper per ASTM B3 and ASTM B8
Insulation:
Polyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes
Filler:
Polypropylene filler on cables with 5 or less conductors
Binder:
Polyester flat thread binder tape applied for cables with more than 5 conductors
Shielding:
5 mils tape shield
Rip Chord:
Rip chord for ease of jacket removal
Overall Jacket:
Polyvinyl Chloride (PVC) Jacket
Specifications:
• Size: 10 AWG
• Number of Conductors: 37
• Diameter Over Conductor (inch): 0.111
• Insulation Thickness (Mil): 30
• Jacket Thickness (Mil): 80
• Approx. OD (In): 1.355
• Copper Weight (Lbs/1000'Ft): 1198
• Approx. Weight (Lbs/1000'Ft): 1755
• DC Resistance Ω /1000ft: 1.040
• AC Resistance @ 90°C Ω /1000ft: 1.300
• Min Bending Radius (In): 6.8
• Allowable Ampacity At 60°C (Amp): 12
• Allowable Ampacity At 75°C (Amp): 14
• Allowable Ampacity 90°C (Amp): 16
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460
