1 AWG ROYAL DLO Diesel Locomotive Cable RHH/RHW HDFPC 2KV
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
1 AWG DLO Diesel Locomotive Cable RHH/RHW HDFPC 2KV
Applications:
HDFPC-DLO is a 2KV flexible power cable with a variety of possible applications such as but not limited to: Drilling rigs, railroad
and transit car wiring, mining and other industrial equipment, and as flexible motor leads and wind turbine applications. The cable
is suited for use in wet and dry areas, conduits, ducts, troughs, trays, and where superior electrical properties are desired. The
maximum continuous conductor temperature for normal operation is 90°C wet or dry. HDFPC-DLO is oil, heat, flame, abrasion,
and sunlight resistant. Approved for use per the NEC® as Type RHH/RHW-2 and per the CE Code as 2KV Type RW90. These cables are capable of operating continuously at the conductor temperature, not in excess of 90°C for normal operation in wet and
dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Sizes 1/0 and Larger Rated For CT Use
CONSTRUCTION:
Conductors: Flexible Stranded Rope-Lay Class I Tinned Copper per ASTM B33 and B172
Binder Tape: Mylar Tape
Insulation: 2 layers Thermoset Ethylene Propylene Diene Monomer / Thermoset Chlorinated Polyethylene (EPDM/CPE)
Also Known As:
Diesel Locomotive Cable, DLO Cable, DLO Wire, Locomotive Cable, Type DLO Cable, DLO, DLO Welding Cable, DLO Heavy-Duty Cable, ROYAL DLO Cable
Standard:
• ASTM B3 - Soft or Annealed Copper
• ASTM B33 - Tinned Soft or Annealed Copper
• B172 - Rope-Lay-Stranded Copper Conductors Having Bunch Stranded Members
• UL Subject 2806 - Type HDFPC-DLO
• UL 44 - Type RHH/RHW-2
• CSA C22.2 No. 38 - Type RW90. (#12 and #10 AWG are not RW90)
• MSHA - P-07-KA100013
• IEEE 1202/FT4 - Flame Test (70,000 Btu/hr Vertical Tray Test). #8 and larger CSA. 1/0 and larger UL
• UL 1685 - Vertical-Tray Fire-Propagation and Smoke-Release Test
• ICEA S-95-658 (NEMA WC70) Power cables rated 2000 volts or less for the distribution of electrical energy
Specifications:
Part No: TBA
Size: 1 AWG
Conductor Strands: 210/#24
Diameter: 0.335 Inches
EPDM Layer: 0.080
CPE Layer: 0.045
Nominal Overall Diameter: 0.560
Weight Lbs/1000ft: 260
Bend Radius: 4.48
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet