50 Cable Gland PX2KW Globally Steel Metal Armour Clamping SWA Epoxy Barrier Explosive Atmosphere
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
50 Cable Gland PX2KW Globally Steel Metal Armour Clamping SWA Epoxy Barrier Explosive Atmosphere
Allowable Ampacity for 50 Cable Gland PX2KW Globally Steel Metal Armour Clamping SWA Epoxy Barrier Explosive Atmosphere : 100 Amps
Also Known As:
Cable Gland, PX2KW Cable Gland, Barrier Gland, Armour Clamping Gland, Atmosphere Gland
Application:
• Metal-to-metal armour clamping
• Direct & remote installation
• Compound barrier type flameproof seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Integral protected deluge seal
• -60°C to +85°C
• Class I Zone 1, 21 and Zone 2, 22 Class I Division 1 & 2 ABCD
• Globally marked, IECEx, ATEX, UL & cCSAus
• EMC tested
Construction:
• Design Specification: BS 6121:Part 1:1989, IEC 62444, EN 62444
• Mechanical Classifications*: Impact = Level 8, Retention = Class D
• Enclosure Protection: IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
• Electrical Classifications *: Category B
• ATEX Certificate: SIRA13ATEX1072X, SIRA13ATEX4078X
• Code of Protection: II 2G, II 1D, Ex d IIC Gb, Ex e IIc Gb, Ex ta IIIC Da
II 3G Ex nR IIC Gc, IM2 Ex d I Mb, Ex e I Mb
• Compliance Standards: EN 60079-0,1,7,15,31
• IECEx Certificate: IECEx SIR 13.0027X, IECEx SIM 14.0008X
• Code of Protection: Ex d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex d I Mb, Ex e I Mb
• Compliance Standards: IEC 60079-0,1,7,15,31
• cCSAus Certificate: 2288626
• CSAus Code of Protection***: Class I, Div. 2 Groups A, B, C and D; Class II, Div. 2 Groups F and G; Class III, Div. 2; Type 4X: Oil Resistant II: Class I, Zone 1 AEx d IIC Gb, AEx e IIC Gb, Class I, Zone 2 AEx nR IIC Gc, Class I, Zone 20 AEx ta IIIC Da
• cCSA Code of Protection***: Class I, Div. 2 Groups A, B, C and D; Class II, Div. 2 Groups F and G; Class III, Div. 2; Type 4X: Oil Ex d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da
• Compliance Standards: CAN/CSA-C22.2 No 0,18,25,30,94,174, CAN/CSA-E60079-0,1,7,15,31 CAN/CSA-E61241-1-1 Part 1-1, ANSI/UL 514B Ed 5, ANSI/UL 50 Ed 11, ANSI/UL 2225 Ed 4, UL60079
• UL Certificate (20s16 - 100): E161256C
• Code of Protection: Class I, Div 2, Groups A,B,C,D; Class II, Div 2, Groups F,G
• Compliance Standards: UL 2225, CSA C22.2 No 174, UL 514B, CSA C22.2 No 18
• EAC Certificate: TC RU C-GB.AA87.B.00487
• UkrSEPRO: UA.TR.047.C.0644-15
• KCC Certificate: 14-GA4BO-0252X
• CCOE / PESO (India) Certificate: P333688
• NEPSI Certificate: GYJ13.1140X, GYJ13.1282X
• INMETRO Approval: TÜV 12.2073X
• RETIE Approval: 03866
• Marine Approvals: LRS: 01/00172, DNV: TAE00000Y, ABS: 14-LD234401A-4-PDA, BV: 43180/A1BV
• Ingress Protection Rating **: IP66, IP67 & IP68**
• Deluge Protection Compliance: DTS01 : 91
• Cable Gland Material: Electroless Nickel Plated Brass, Brass, Stainless Steel, Aluminium
• Seal Material: CMP SOLO LSF Halogen Free Thermoset Elastomer / Epoxy Barrier Compound
• Cable Type: Single Wire Armour (SWA), Aluminium Wire Armour (AWA)***
• Armour Clamping: Detachable Compound Tube / Cone & AnyWay Universal Clamping Ring
• Sealing Technique: Unique CMP ‘LRS’ Outer Seal (Load Retention Seal)
• Sealing Area(s): Inner Compound Barrier & Cable Outer Sheath
• Optional Accessories: Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs
• Optional Installation Tools: Spanners, Armour Former Tool
Specification :
• Cable Gland Size: 50
• Available Entry Threads "C" (Alternate Metric Thread Lengths Available) Standard Metric: M20
• Available Entry Threads "C" (Alternate Metric Thread Lengths Available) Standard Thread Length (Metric) "E": 15.0
• Available Entry Threads "C" (Alternate Metric Thread Lengths Available) Standard NPT: 2"
• Available Entry Threads "C" (Alternate Metric Thread Lengths Available) Standard Thread Length (NPT) "E": 26.9
• Available Entry Threads "C" (Alternate Metric Thread Lengths Available) Option NPT: 2 ½"
• Number of Cores : 89
• Diameter Over Conductors "A" : 41.0
• Cable Bedding Diameter "G" Max : 41.3
• Overall Cable Diameter "B" Min : 40.4
• Overall Cable Diameter "B" Max : 53.0
• Armour Range Min: 2.0
• Armour Range Max: 2.5
• Across Flats "D" Max: 70.1
• Across Corners "D" Max: 77.1
• Protrusion Length "F": 77.1
• Combined Ordering Reference (*Brass Metric) Size: 50
• Combined Ordering Reference (*Brass Metric) Type: PX2KW
• Combined Ordering Reference (*Brass Metric) Ordering Suffix: 1RA
• Shroud: PVC21
• Cable Gland Weight: 2.755 Lbs
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460