10/2 Teck 90 Bare Copper Aluminum Interlocked Armored Control Cable With Ground 1KV

Where are we? 4 Continents 9 Countries


Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
10/2 Teck 90 Bare Copper Aluminum Interlocked Armored Control Cable With Ground 1KV
Application:
For exposed or concealed wiring in wet or dry locations. For use in ventilated, non-ventilated and ladder type cable troughs and ventilated flexible cableway in wet, dry, or hazardous locations. Sunlight Resistant. Typical applications are for control. lighting and power circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants.1000V Multi Conductor, 14-10 AWG Copper, FT4 - Flame Retardancy Rating, XLPE Insulation, Aluminum Interlocked Armour, Sunlight Resistant, -40°C - 90°C, Rated HL, AG14.
Also Known As:
10 AWG Teck90 Canadian Copper Construction Wire, 10 AWG Teck90, Teck90 Cable, Teck90 Wire, Teck90 Interlocked Armoured Cable, 10 AWG Teck 90 Bare Copper Aluminum, 10 AWG TECK90 Armored Control Cable.
Construction:
• Conductor: Class B stranded copper, compressed or compact, in accordance with ASTM B3 and B8
• Insulation: Cross-Linked Polyethylene (XLPE), Colour Code: 2/C black, white; 3/C red, black, blue; 4/C red, black, blue, white
• Grounding Conductor: Uninsulated Class B stranded grounding conductor
• Inner Jacket: Black Polyvinyl Chloride (PVC)
• Armor: Aluminum Interlocked Armor (AIA)
• Overall Jacket: Black PVC (optional colours available)
Standards:
• ASTM B3 Soft or Annealed Copper Wire
• ASTM B8 Concentric-Lay-Stranded Copper Conductors
• CSA C22.2 No. 174 Cables in Hazardous Locations
• CSA C22.2 No. 131 Type TECK 90 Cable
• CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating
• CSA HL - for Hazardous Locations rating
• CSA SUN RES - for Sunlight Resistant rating
• CSA AG14 - Acid Gas Compliance
• IEEE 383 Flame Test (70,000 btu)
• IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
Features:
• -40°C - CSA Cold Bend and Impact Temperature
• -40°C - Min. Installation Temperature
• 90°C - Max. Continuous Operating Temperature
Specifications:
• Size: 10 AWG
• Conductor Number: 2
• Number of Strands: 7
• Insulation Thickness (Mil): 45
• Ground No. x AWG: 1x12
• Inner Jacket Thickness (mil): 65
• Diameter Over Armor (inch): 0.723
• Overall Jacket Thickness (mil): 45
• Approx. OD (In): 0.813
• Approx. Weight (Lbs/1000'Ft): 303
• Min Bending Radius (In): 5.6
• Max Pull Tension lb: 166
• Allowable Ampacity In Raceway 90°C† (Amp): 40
Compatiable with manufacturer |