Sumsave® 113700030760000 600 MCM 3C Bare Copper Concentric Shield Thermoplastic AS RZ1KZ1-K 0.6/1kV Screened Cable

Where are we? 4 Continents 8 Countries


Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
Sumsave® 113700030760000 600 MCM 3C Bare Copper Concentric Shield Thermoplastic AS RZ1KZ1-K 0.6/1kV Screened Cable
Allowable Ampacity for Sumsave® 113700030760000 600 MCM 3C Bare Copper Concentric Shield Thermoplastic AS RZ1KZ1-K 0.6/1kV Screened Cable: 100 Amps
Application:
Screened power cable for industrial use, distribution boxes, outdoor lighting, as well as control cable for signal transmission. Driver concentric can be used as a neutral or as a ground conductor. Simultaneously, it is also allowed to use it as a screen. Its use is recommended as a cable for the interconnection between frequency inverters and motors. In the event of a fire, it does not emit toxic substances or corrosive gases, and it does not spread the fire, thus protecting public health and preventing damage to electronic equipment.
Also Known as:
Sumsave® AS RZ1KZ1-K Cable, Sumsave Cable, RZ1KZ1-K Cable, Control Cable, Sum Cable, Power Cable, Screened Cable
General properties:
• Construction regulations UNE 21123-4
• Flame retardant according to EN60332-1-2 / IEC60331-1-1
• Fire retardant according to EN50266 / IEC60332-3
• e halogen according to EN50267-2-3 C60754-2
• smoke opacity according to EN50268 / IEC61034
• Low corrosivity of gases EN50267-2-3 / IEC60754-2
Technical characteristics:
• Service voltage 0.6/1kV
• Test voltage 3,500V AC for 5 min.
• Service temperature –40ºC to 90ºC in fixed installation (–5ºC during installation)
• Maximum conductor temperature 90ºC (250ºC in case of short circuit)
• Electrical resistance according to UNE 60228
• Maximum allowable current according to IEC60364
• 12 x Ø Minimum bending radius in fixed installation
Specification:
AWG Size: 600 MCM
Number of Conductor: 3
Conductor: Bare Copper
Conductor x Section: 3x300 mm²
Dry Screen: 150 mm²
Exterior: 70.0 mm
Resistance Ω/km at 20ºC: 0.0641
try (40ºC) To (on air): 565.0
Rated Voltage: 0.6/1kV
Weight: 8,997.66 lbs/MFT
Part Number: 113700030760000
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color