12 AWG 23C TC Control Cable XLP Insulation VW-1 Rated PVC Jacket 600V
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
12 AWG 23C TC Control Cable XLP Insulation VW-1 Rated PVC Jacket 600V
Application:
• UL listed and OSHA acceptable. Recognized for use in Class 1or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Specifically approved for direct burial, wet or dry locations and outdoors in cable trays where a sunlight resistant rating is required. Designed for control, power, lighting, telemetering, signals and relay or traffic control where a low loss, high temperature insulation is specified.
Scope:
• This specification covers multiconductor cables having cross-linked polyethylene (XLP) insulation with an overall gas/vapor-tight polyvinyl chloride (PVC) jacket; conforming to Article 318 "Cable Trays" and Article 340 "Power and Control Cable Type TC" of the 1999 National Electric Code, and Standard 1277 of Underwriters Laboratories, Inc. They meet the requirements of the ICEA T-29-520 and T-30-520 flame tests as well as the 70,000 BTU "Cable Tray Propagation Test" per IEEE-383 and show reserve capabilities by also passing the 210,000 BTU flame test. Rated 600 Volts, 90°C wet and dry. Sizes 14, 12, and 10 AWG conductors are UL Type XHHW-2. They also meet the CSA FT4 and the IEEE 1202 70,000 BTU flame tests
Also Known As:
12 AWG 23C TC Type Control Cable, 12 AWG 23C XLP Control Cable, 12/23C VW-1 Rated PVC Cable, Control Cable, 12 AWG 23C PVC Jacket Control Cable, TC Control Cable.
Construction:
Conductors:
Bare, soft annealed copper per ASTM B-3
Sizes 18 and 16 AWG
Bunch stranded, class K (.010" #30 strands) per ASTM
B-174, and UL-62
Sizes 14, 12 and 10 AWG (XHHW-2)
Concentric stranded, class B (7 strands) per ASTM B-8 and UL44 paragraph 12.6. (An opaque separator is applied between
the conductor and the insulation to facilitate stripping.)
Insulation:
Cross-linked polyethylene
Sizes 18 and 16 AWG: UL-1581 table 50.241
Sizes 14, 12, and 10 AWG: UL-44 class XL compound
and ICEA S-73-532 part 3
Thickness
Sizes 18 and 16 AWG: UL-62 table 6.1 (RFH-2)
Sizes 14, 12, and 10 AWG: UL-44 table 15.3 and ICEA
S-73-532
Cabling Assembly:
Three or more conductors are assembled round with fillers as needed. A tape binder is applied over the assembly. Sizes 14, 12 and 10 AWG have a nylon ripcord inserted under the jacket for ease of stripping. Two conductors are assembled flat parallel (round, with fillers as needed, is available upon request).
Overall Jacket:
Gas/vapor-tight Polyvinyl Chloride (black) per UL-1277 table
10.1 & ICEA S-73-532 part 4 table 4-2.
Thickness - Specified herein
Specifications:
• AWG: 12
• No. of Conductors: 23
• Overall Jacket Thickness (Mils): 80
• Approx. Outside Diameter (In): 1.043
• Approx. Weight 1000 FT (Pounds): 790
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet