Three Conductor Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV - 35 kV
Select a Gauge
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Name | Length | Price (Per FT.) | Action | |
---|---|---|---|---|
Product Name
6 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV |
Length
/FT
|
Price (Per FT.)
Call 516-482-6313 for pricing
|
Action
|
|
Product Name
4 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV |
Length
/FT
|
Price (Per FT.)
Call 516-482-6313 for pricing
|
Action
|
|
Product Name
2 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV |
Length
/FT
|
Price (Per FT.)
Call 516-482-6313 for pricing
|
Action
|
Product Information
Specification
Application:
• Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.
• May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.
Also Known As:
MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.
Standards:
• UL 1072
• Medium Voltage Power Cables.
• ICEA S-93-639/NEMA WC74
• 5 kV – 46 kV Shielded Power Cables.
• ICEA S-97-682
• Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.
• AEIC CS8
• Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.
Features:
• UL Listed as MV-90.
• Rated as Sunlight Resistance for CT use, 1/0 AWG and larger.
• Oil Resistance I jacket.
• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.
Construction:
• Conductor: Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.
• Conductor Shield: Semi conducting cross-linked polyethylene (XLPE).
• Insulation: Thermoset crosslinked polyethylene (XLPE).
• Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
• Metallic Shield: Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap
• Grounding (Optional): One or three soft annealed bare copper or covered conductors cabled with phase conductors.
• Assembly: Conductors cabled with non hygroscopic fillers, as required and binder tape.
• Jacket: Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
Download PDF Spec Sheet