2 Solid Aluminum Conductor 15KV URD - Full Neutral 100%
Applications:
15kV cable is a medium voltage cable, installed through direct burial or in conduit, for underground distribution. This aluminum direct burial cable with copper shielding performs for normal operations at 90°C, emergencies at 130°C, and short-circuiting conditions at 250°C. The 15kV cable does not require pulling lubricants and is used in both wet and dry locations for 15,000 volts power circuits.
Also Known As:
2 solid 15kv cable, 2 solid medium voltage cable, 2 solid medium voltage wire, 2 solid copper tape shield, 2 solid copper shielding, 2 solid bury cable, 2 solid direct burial cable, 2 solid direct burial power cable, 2 solid medium voltage power cables, 2 solid aluminum direct burial cable.
Standards:
- ASTM B230, B231, B609
- ANSI/ICEA S-94-649
- AEIC CS-8
- RUS ACCEPTED
- For 90°C continuous, 130°C emergency and 250°C short-circuit operation
Construction
Conductors:
15kV cable aluminum conductor is made of 1350 aluminum series, which is solid or compressed and soft drawn stranded in accordance with ASTM. The conductor has a filling compound and is water-blocked.
Insulation:
The 15kV aluminum urd cable has TR-XLPE insulation, which offers high dielectric strength. EPR insulation is also available.
Metal shield:
The metal shield is concentric neutral and consists of solid bare copper wires that cover the insulation shield.
Jacket:
The 15kV cable jacket is black color coded for simpler identification and consists of linear lows density polyethylene (LLDPE). The jacket offers protection from heat, sunlight, and abrasion.
Specifications:
- Conductor Size (AWG/kcm): 2 SOL
- Insulation Thickness (mils): 175
- Conductor Diameter (inches): 0.258
- Insulation Diameter (inches): 0.65
- Insulation Shield Diameter (inches): 0.72
- Overall Jacket Diameter (inches): 0.96
- Net Weight (lbs./kft.): 455
Compatible with Manufacturer |
|
Priority Wire & Cable : | 2-0115KXSO175MALJ |
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet