HVTECK Copper 1/C 220 mil TRXLPE TS AIA 15kV 133% IL Red PVC Jacket CSA

Where are we? 4 Continents 9 Countries


Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
HVTECK Copper 1/C 220 mil TRXLPE TS AIA 15kV 133% IL Red PVC Jacket CSA
Application:
The 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs /FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.
Also Known As:
HVTECK 15kV cable, TRXLPE 220 mil 15kV wire, 133% insulation level cable, Copper 1 conductor HV cable, CSA approved 15kV cable, Red PVC jacket HVTECK wire, 15kV AIA cable CSA, 15kV shielded TRXLPE cable, HVTECK 1/C armored cable, 15kV copper underground cable.
Construction:
• Conductor: Class B compressed stranded bare copper per ASTM B3 and ASTM B8
• Conductor Shield: Semi-conducting cross-linked copolymer
• Insulation: 220 Mils Tree Retardant Cross Linked Polyethylene 133% insulation level
• Insulation Shield: Strippable semi-conducting cross-linked copolymer
• Copper Tape Shield: Helically wrapped 5 mil copper tape with 25% overlap
• Inner Jacket: PVC inner jacket
• Armour: Aluminum Interlocked Armour (AIA)
• Overall Jacket: Red Polyvinyl Chloride (PVC) Jacket
Standards:
• ASTM B3 Soft or Annealed Copper Wire
• ASTM B8 Concentric-Lay-Stranded Copper Conductors
• CSA C22.2 No. 174 Cables in Hazardous Locations
• CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
• CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
• CSA C68.3 Shielded & Concentric Neutral Power Cable - 5 to 46 kV
• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating
• CSA HL - for Hazardous Locations rating
• CSA SUN RES - for Sunlight Resistant rating
• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
• ICEA T-29-520 Flame Test (210,000 BTU/Hr)
• IEEE 383 Flame Test (70,000 btu)
• IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test (1/0 and Larger)
• FT1 Flame Test (1,706 BTU/Hr nominal - Vertical Wire Flame Test)
• AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460