750 MCM HVTECK Copper 220 mil NLEPR CB AIA 15KV 133% IL Red PVC Jacket
/es/collections/hvteck-copper-1-c-220-mil-nlepr-cb-aia-15kv-133-il-red-pvc-jacket-csa/products/750-mcm-hvteck-copper-220-mil-nlepr-cb-aia-15kv-133-il-red-pvc-jacket-csa
Items in Cart ()
View cart

750 MCM HVTECK Copper 220 mil NLEPR CB AIA 15KV 133% IL Red PVC Jacket CSA

750 MCM HVTECK Copper 220 mil NLEPR CB AIA 15KV 133% IL Red PVC Jacket CSA
Roll over image to Zoom
750 MCM HVTECK Copper 220 mil NLEPR CB AIA 15KV 133% IL Red PVC Jacket CSA
SKU: NNC587685
hvteck-copper-1-c-220-mil-nlepr-cb-aia-15kv-133-il-red-pvc-jacket-csa
Min Length: 1 FT
Max Length: 10000 FT
Price:
Precio habitual
$0.00 /FT
Precio de oferta
$0.00 /FT
Los gastos de envío se calculan en la pantalla de pagos.
Free Shipping: On orders above $1000
La cantidad debe ser 1 o más

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 9 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Product Information
Specification

750 MCM HVTECK Copper 220 mil NLEPR CB AIA 15KV 133% IL Red PVC Jacket CSA

Application:

The 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs /FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.

Also Known As:

750 MCM HVTECK Copper 1/C 15kV cable, 220 mil NLEPR 15kV copper wire, HVTECK 15kV red PVC jacket wire, 15kV Copper NLEPR cable CSA, 750 MCM HVTECK 220 mil 133% IL cable, Red PVC jacketed copper wire 15kV, Copper 1/C 15kV insulated wire, 220 mil Copper AIA 15kV cable, 15kV CSA approved copper wire, 750 MCM HVTECK 220 mil NLEPR 15kV cable.

Construction:

• Conductor: Class B compressed stranded bare copper per ASTM B3 and ASTM B8
•  Conductor Shield: 
Semi-conducting cross-linked copolymer
• Insulation: 
220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level
• Insulation Shield: 
Strippable semi-conducting cross-linked copolymer
• Concentric Shield: 
Concentrically applied copper bond / shield wires. Complies with greater than the minimum requirement as per Table 44, CSA Standard C68.10 and Table 16A, Canadian Electrical Code Part 1
• Neutral Separator: 
Mylar tape
• Inner Jacket: 
PVC inner jacket
• Armour: 
Aluminum Interlocked Armour (AIA)
• Overall Jacket: 
Red Polyvinyl Chloride (PVC) Jacket

Standards:

• ASTM B3 Soft or Annealed Copper Wire
• ASTM B8 Concentric-Lay-Stranded Copper Conductors
• CSA C22.2 No. 174 Cables in Hazardous Locations
• CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
• CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
• CSA C68.3 Shielded & Concentric Neutral Power Cable - 5 to 46 kV
• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating
• CSA HL - for Hazardous Locations rating
• CSA SUN RES - for Sunlight Resistant rating
• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
• ICEA T-29-520 Flame Test (210,000 BTU/Hr)
• IEEE 383 Flame Test (70,000 btu)
• IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test (1/0 and Larger)
• FT1 Flame Test (1,706 BTU/Hr nominal - Vertical Wire Flame Test)
• AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)

Specifications:

• Size: 750 MCM
• Number of Strands:  61
• Diameter Over Conductor (inch):  0.968
• Diameter Over Insulation (inch):   1.464
• Insul. Thickness mil: 220
• Diameter Over Insulation Shield (inch):  1.524
• Concentric Neutral No. x AWG:  21x12

• Inner Jacket Thickness (mil): 110 
• Diameter Over Armor (inch): 2.276
• Overall Jacket Thickness mil :  75
• Approx. OD inch :  2.426
• Copper Weight lb/1000ft:  2880
• Approx. Weight (Lbs/1000'Ft):  4617
• Min Bending Radius (In):   29.1
• DC Resistance @ 25°C Ω /1000ft:  0.014
• AC Resistance @ 90°Ω /1000ft:  0.023
• Inductive Reactance @ 60HzΩ/1000ft:  0.043
• Allowable Ampacity In Air 90°C Amp:  706
• Allowable Ampacity Directly Buried 90°C Amp: 551

Compatible with Manufacturer

Southwire 587685

*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet

 

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460

Win an Exclusive prize!

Enter your full name and email to spin the wheel for a chance to win

Powered by CareCart